The HAL LED has been designed with a reduced power measurement range with greater resolution than the HAL 104, making it ideal for the testing of low power electronics such as LED lighting.
Features | 101 | 103 | 104 | LED |
Earth/Ground Bond | ||||
AC Flash/Hipot | ||||
DC Flash/Hipot | ||||
DC Insulation Resistance | ||||
ARC Detection | ||||
Leakage | ||||
Load Power | ||||
Load Power (200mVA resolution) | ||||
Power Factor | ||||
Results Memory | ||||
Automation Option | ||||
Barcode scanner/printer Option | ||||
View tester | View tester | View tester | View tester |
The HAL LED is designed to ensure maximum productivity and efficiency when safety testing on LED and other luminaire production lines; while the high resolution power measurement allows for greater quality control measures to be implemented. The HAL LED tests in accordance with UL 1598, UL 8750.
200mVA Resolution Power Measurement
LED lighting is fast becoming the choice for ‘green’ conscious consumers; manufacturers are striving to produce more efficient lighting solutions for a competitive market.
With 200mVA resolution, the HAL LED is designed so that manufacturers can measure the output of every product manufactured to ensure it falls within acceptable power limits.
This gives the manufacturer peace of mind that correct components, such as LED drivers, were fitted at time of manufacture.
The HAL LED is appropriate for medium-large scale electrical manufacturers: LED lighting manufacturers, LED lighting importers, QA and product auditing departments and manufacturers of low powered equipment
Traceable Results
With quality systems placing more pressure on manufacturers to provide traceable, accurate results the HAL LED eliminates the pressure of manually logging test results.
Date and Time stamps are applied to each product tested along with an optional field a product identifier such as a serial or batch number. A large memory capable of storing 6000 tested products will capture the daily results of even the busiest production line.
Flexible User Configurable Test Sequences
The HAL LED can store up to 50 test sequences in its automatic mode configuration. Each test sequence can comprise of up to 5 individual test (not including repeats).
Once configured, automatic mode provides a structured and repeatable method of testing, ensuring that the required test parameters and timings are adhered to during end-of-productionline test requirements.
Designed with Safe Testing Practices in Mind
In order to aid compliance with safe test area requirements (EN 50191) the HAL LED utilises a number of safety features.
Isolated test outputs when performing Flash (HiPot) and Insulation resistance tests reduce the potential for shock.
The built-in guard switch enables automatic disconnection of test voltages if opened, ideal for ensuring safety if a person accidentally enters the test area during a potentially hazardous test. That coupled with a ‘plug and play’ style beacon port enables clear identification when high voltage testing is being performed.
A leading manufacturer of commercial and industrial LED lighting, NET LED, has improved the electrical safety testing of its products by using low power multi-function LED testers ...
Investment in new test technology has enabled a leading manufacturer of industrial and commercial lighting products to significantly reduce production line test times, increasing ...
JMS Janitorial Supplies, who undertakes the refurbishment of thousands of Karcher electric pressure washers sent to its site in Surrey by retailers from across the UK, uses 6 HAL ...
Martech UK Ltd, which designs and manufactures a wide range of energy efficient light fittings, has improved its electrical safety testing procedure by installing an automatic sys...
AC Flash / HiPot Test | |
---|---|
Programmable Voltage Range | 0.10 kV-5.00 kV (10V/Step Resolution) |
Frequency Independent of Supply | 50 or 60 Hz |
Voltage Display Range and Accuracy | 0.10 kV - 5.00 kV ± 1% ± 5 Counts |
Voltage Display Resolution | 0.01 kV |
Current Display Range and Accuracy | 0.01mA-20.00mA ± 1% ± 5 Counts |
Current Display Resolution | 0.01mA |
Selectable Range of Pass/Fail Levels | 0.01mA-20.00mA |
Maximum Current Output | 20.00mA @5kV |
Optional Arc Detection | 9 Levels |
Insulation Resistance Test | |
---|---|
DC Output Voltage | Default Spec Value250V, 500, or 1000V Selectable |
Display Range | 0.01MΩ-500MΩ |
Display Range/Accuracy | 0.03MΩ - 350MΩ ± 5% ± 5 Counts 350MΩ-500MΩ Indication Only |
Display Resolution | 0.01MΩ |
Pass/Fail Level | 0.00MΩ-500MΩ |
Compliance Test Ranges | |
---|---|
Current/Load Resistance/Time | 5A - 1000mΩ - Continuous 10A - 500mΩ - Continuous 25A - 200mΩ - Continuous 30A - 150mΩ - 60 Secs 40A - 100mΩ - 30 Secs |
Settable Output Current Range | 0.1A - 40.0A |
Selectable Range of Pass/Fail Levels | 0-1500 mΩ |
Output Power Measurement | |
---|---|
Display Range and Accuracy | 000.0VA to 99.9VA ± 5% ±5 digits 100.0VA - 999.9VA ± 5% ± 2 digits |
Selectable Range of Pass/Fail Levels Measurement Circuit Characteristics Crest Factor: | 000.2 - 1000 VA |
Crest Factor: | |
Maximum Crest Factor = 2 Harmonic Content: Accuracy degradation is directly proportional to % harmonic content. |
Leakage Current Measurement | |
---|---|
Display Range and Accuracy | 0.10mA-20.00mA ± 1% ± 5 Counts |
Display Resolution | 0.01mA |
Selectable Range of Pass/Fail Levels | 0.01mA-20mA |
DC Flash / HiPot Test | |
---|---|
Programmable Voltage Range | 0.10 kV-6.00kV (10V/Step resolution) |
Voltage Display Range and Accuracy | 0.10kV-6.00kV ± 1% ± 5 Counts |
Voltage Display Resolution | 0.01 kV |
Current Display Range and Accuracy | 0.01mA-10.00mA ± 1% ±5 Counts |
Current Display Resolution | 0.01mA |
Selectable Range of Pass/Fail Levels | 0.01mA-10.00mA |
Maximum Current Output | 10.00mA |
Optional Arc Detection | 9 Levels |
Earth / Ground Bond Test | |
---|---|
Test Voltage | Nominal 6V AC |
Frequency | 50 or 60Hz (Independent of supply) |
Display Range and Accuracy | 0-1500mΩ ±2% ±5 Counts |
Display Resolution | 1mΩ |
Power and Leakage Test | |
---|---|
Power Output Rating Test Voltage | 80V - 300V AC 20A nominal (VinVout) |
Maximum Power Output | 999.9VA |
Single Phase Power Factor Measurement | |
---|---|
Display Range and Accuracy Ratio | 0.000-1.000* *Displayed value for indication only |
Selectable Range of Pass/Fail Levels | 0.000-1.000 |
Touch Current Measurement | |
---|---|
Display Range and Accuracy | 0.02mA-5.00mA ± 1% ± 5 Counts |
Display Resolution | 0.01 |
Selectable Range of Pass/Fail Levels | 0.02mA-5.00mA |
Measuring Device | IEC/EN 60990 Fig 4 |
Register your HAL LED today to activate your warranty and to stay up to date with the latest product updates, news and support information.