Flash/Hipot Test (Class II) | |
---|---|
Test Voltage Class II | 3.0kV AC |
Range | 0.1 – 10.00mA |
Resolution | 0.01mA |
Accuracy | +/- 5% +/- 2 digits |
Pass Levels | Selectable up to 10mA |
DC Insulation Test | |
---|---|
Test Voltages | 250V, 500VDC |
Range | 100kΩ - 50MΩ |
Accuracy | +/- 5% +/- 2 digits |
Substitute Leakage (Short to case test) | |
---|---|
Voltage | 40VAC nominal at 230V/110V supply |
Range | 0.1 – 20mA |
Resolution | 0.01 mA |
Accuracy | +/- 10% +/- 2 digits (1.00 – 20 mA) |
Pass Levels | Selectable up to 15 mA |
Polarity | |
---|---|
Test performed | Live & Neutral continuity & polarity |
General Specifications | |
---|---|
Dimensions (w x h x d) | 450 x 410 x 155mm / 17.7 x 16.1 x 6.1” |
Weight | 9kg / 19.8lb |
Operating Voltage Range | 103V – 126V, 207V – 253V, 45Hz – 65Hz |
Operating Temperature | 0 – 40°C |
EN 50191 | Compliant when used with appropriate accessories |
Flash/Hipot Test (Class I) | |
---|---|
Test Voltage Class I | 1.5kV AC |
Display Range | 0.1 – 10.00mA |
Resolution | 0.01mA |
Accuracy | +/- 5% +/- 2 digits |
Pass Levels | Selectable up to 10mA |
Earth/Ground Bond Test | |
---|---|
Test Voltage | 6VAC (open circuit) |
Test Currents | 25A, 10A, 4A, 100mA AC into short circuit |
Range | 0.04 - 20Ω |
Resolution | 0.01Ω |
Accuracy | +/- 5% +/- 2 digits |
Pass Levels | User selectable |
Earth Leakage (Load Leakage) | |
---|---|
Voltage | Mains Supply |
Range | 0.1 – 20mA |
Resolution | 0.01 mA |
Accuracy | +/- 10% +/- 2 digits (1.00 – 20mA) |
Pass Levels | Selectable up to 10 mA |
Power/Run/Load Test | |
---|---|
Measured Load | 0 – 4.2kVA |
Resolution | 0.01 kVA |
Accuracy | +/- 10% of reading, +/- 2 digits |
External Connections | |
---|---|
Serial Port | |
Parallel Port | |
Guard Switch | |
Beacon |