DC Flash / HiPot Test | |
---|---|
Programmable Voltage Range | 0.10 kV-6.00kV (10V/Step resolution) |
Voltage Display Range and Accuracy | 0.10kV-6.00kV ± 1% ± 5 Counts |
Voltage Display Resolution | 0.01 kV |
Current Display Range and Accuracy | 0.01mA-10.00mA ± 1% ±5 Counts |
Current Display Resolution | 0.01mA |
Selectable Range of Pass/Fail Levels | 0.01mA-10.00mA |
Maximum Current Output | 10.00mA |
Optional Arc Detection | 9 Levels |
Earth / Ground Bond Test | |
---|---|
Test Voltage | Nominal 6V AC |
Frequency | 50 or 60Hz (Independent of supply) |
Display Range and Accuracy | 0-1500mΩ ±2% ±5 Counts |
Display Resolution | 1mΩ |
Power and Leakage Test | |
---|---|
Power Output Rating Test Voltage | 80V - 300V AC 20A nominal (VinVout) |
Maximum Power Output | 999.9VA |
Single Phase Power Factor Measurement | |
---|---|
Display Range and Accuracy Ratio | 0.000-1.000*[br]*Displayed value for indication only |
Selectable Range of Pass/Fail Levels | 0.000-1.000 |
Touch Current Measurement | |
---|---|
Display Range and Accuracy | 0.02mA-5.00mA ± 1% ± 5 Counts |
Display Resolution | 0.01 |
Selectable Range of Pass/Fail Levels | 0.02mA-5.00mA |
Measuring Device | IEC/EN 60990 Fig 4 |
AC Flash / HiPot Test | |
---|---|
Programmable Voltage Range | 0.10 kV-5.00 kV (10V/Step Resolution) |
Frequency Independent of Supply | 50 or 60 Hz |
Voltage Display Range and Accuracy | 0.10 kV - 5.00 kV ± 1% ± 5 Counts |
Voltage Display Resolution | 0.01 kV |
Current Display Range and Accuracy | 0.01mA-20.00mA ± 1% ± 5 Counts |
Current Display Resolution | 0.01mA |
Selectable Range of Pass/Fail Levels | 0.01mA-20.00mA |
Maximum Current Output | 20.00mA @5kV |
Optional Arc Detection | 9 Levels |
Insulation Resistance Test | |
---|---|
DC Output Voltage | Default Spec Value250V, 500, or 1000V Selectable |
Display Range | 0.01MΩ-500MΩ |
Display Range/Accuracy | 0.03MΩ - 350MΩ ± 5% ± 5 Counts[br]350MΩ-500MΩ[br]Indication Only |
Display Resolution | 0.01MΩ |
Pass/Fail Level | 0.00MΩ-500MΩ |
Compliance Test Ranges | |
---|---|
Current/Load Resistance/Time | 5A - 1000mΩ - Continuous[br]10A - 500mΩ - Continuous[br]25A - 200mΩ - Continuous[br]30A - 150mΩ - 60 Secs[br]40A - 100mΩ - 30 Secs |
Settable Output Current Range | 0.1A - 40.0A |
Selectable Range of Pass/Fail Levels | 0-1500 mΩ |
Output Power Measurement | |
---|---|
Display Range and Accuracy | 000.0VA to 99.9VA ± 5% ±5 digits[br]100.0VA - 999.9VA ± 5% ± 2 digits |
Selectable Range of Pass/Fail Levels Measurement Circuit Characteristics Crest Factor: | 000.2 - 1000 VA |
Crest Factor: | |
Maximum Crest Factor = 2 Harmonic Content: Accuracy degradation is directly proportional to % harmonic content. |
Leakage Current Measurement | |
---|---|
Display Range and Accuracy | 0.10mA-20.00mA ± 1% ± 5 Counts |
Display Resolution | 0.01mA |
Selectable Range of Pass/Fail Levels | 0.01mA-20mA |