Specifications

Short Circuit Current Measurement (PV Terminals)
Display Range0.00ADC - 15.00ADC
Measuring Range0.50ADC - 15.00ADC
Maximum Power10kW
Resolution0.01ADC maximum
Accuracy± (1% + 2 digits)
Insulation Resistance (Auto Test Sequence, PV Terminals and Red 4mm Terminal)
Test Voltage Open Circuit250V, 500V, 1000V (as per IEC61557-2)
Test Voltage Specification-0% +20% (open circuit)
Test Voltage @ 1mA>1mA into UN x (1000Ω/V)
Test Current Short Circuit<2mA
Display Range0.05MΩ - 199MΩ
Measuring Range (EN 61557-2)0.05MΩ - 199MΩ
Resolution0.01MΩ maximum
Accuracy0.05MΩ - 100MΩ ± (5% + 5 digits)
101MΩ - 199MΩ ± (10% + 5 digits)
Visible Warning≥ 30V AC or DC at inputs
Circuitry ProtectionTest inhibited if ≥ 30V AC or DC at inputs
Repeat tests as per IEC61557-4Approx 3000 1 second tests
Operating Current (via AC/DC Current Clamp)
Display Range0.1A - 40.0A
Current Measuring Range0.1A - 40.0A DC
0.1A - 40.0A AC 50-60Hz
Resolution0.1A
Accuracy± (5% + 2 digits)
Instrument Dimensions and Weight
Weight0.95kg / 2.1lb
Dimensions26.4 x 10.7 x 5.8cm / 10.4 x 4.2 x 2.3”
DisplayCustom LCD with backlight
Power Source6 x 1.5V AA cells
Battery life>1000 test sequences
Auto power downUser programmable
Onboard memoryUp to 200 complete test datasets
Software compatibility
Compatible with SolarCert software (English language only)
Open Circuit Voltage Measurement (PV Terminals)
Display Range0.0VDC - 1000VDC
Measuring Range5.0VDC - 1000VDC
Resolution0.1VDC maximum
Accuracy± (0.5 % + 2 digits)
EnunciatorsDC voltage polarity correct or reversed
Earth Continuity Resistance Measurement (4mm Terminals)
Test Voltage Open Circuit>4VDC, nominal
Test Current into 2 Ω>200mA
Display Range0.00Ω - 199Ω
Measuring Range (EN 61557-4)0.05Ω - 199Ω
Resolution0.01Ω maximum
Accuracy± (2% + 5 digits)
Test Leads ZeroZero up to 10Ω, by zero button
Visible Warning≥30V AC or DC at inputs
Circuitry ProtectionTest inhibited if ≥30V AC or DC at inputs
Repeat tests as per IEC61557-4Approx 4000 1 second test
Rpe Voltage Measurement (4mm Terminals)
Display Range30V - 440VAC/DC
Voltage Measuring Range30V - 440VDC
30V - 440VAC 50-60Hz
Resolution1V
Accuracy± (5% + 2 digits)
DC Operating Power (via AC/DC Current Clamp and PV Terminals)
Display Range0.00kW - 40kW
Measuring Range0.50kW - 40kW
Resolution0.01kW
Accuracy± (5% + 5 digits)
Connectivity
USB download to PC (CSV format)
Wireless “Solarlink TM” to Survey 200R (range ~30m/100ft)
Service
2 year warranty (subject to terms and conditions, available at /warranty)



Stay in the know
Sign up to our mailing list today to stay up to date with the latest industry news and information from Seaward.

I'd like to talk to a sales advisor

Our team of sales advisors are on hand to help you with any queries you have about our products.